Since generic has the option set to y and other targets now inherit that
choice, there is no behaviour change
Signed-off-by: Yousong Zhou <yszhou4tech@gmail.com>
The option was introduced in upstream linux commit a6484045 ("[TCP]: Do
not present confusing congestion control options by default.").
The option is set to y in generic config and to the moment does not
incur additional size increment. Make it y for all so that packages
such as kmod-tcp-bbr do not have to set it on every occasion
Signed-off-by: Yousong Zhou <yszhou4tech@gmail.com>
Specifications:
SOC: Qualcomm IPQ4018 (DAKOTA) ARM Quad-Core
RAM: 256 MiB
FLASH1: 4 MiB NOR
FLASH2: 128 MiB NAND
ETH: Qualcomm QCA8075
WLAN1: Qualcomm Atheros QCA4018 2.4GHz 802.11b/g/n 2x2
WLAN2: Qualcomm Atheros QCA4018 5GHz 802.11n/ac W2 2x2
INPUT: Reset
LED: Power, Internet
UART1: On board pin header near to LED (3.3V, TX, RX, GND), 3.3V without pin - 115200 8N1
OTHER: On board with BLE module - by cp210x USB serial chip
On board hareware watchdog with GPIO0 high to turn on, and GPIO4 for watchdog feed
Install via uboot tftp or uboot web failsafe.
By uboot tftp:
(IPQ40xx) # tftpboot 0x84000000 openwrt-ipq40xx-generic-glinet_gl-ap1300-squashfs-nand-factory.ubi
(IPQ40xx) # run lf
By uboot web failsafe:
Push the reset button for 10 seconds util the power led flash faster,
then use broswer to access http://192.168.1.1
Afterwards upgrade can use sysupgrade image.
Signed-off-by: Dongming Han <handongming@gl-inet.com>
This commit adds support for Qualcomm IPQ8062 SoC.
IPQ8062 is a lower clock variant of IPQ8064.
CPU and NSS clocks:
- CPU: 384 MHz - 1 GHz
- NSS: 110 MHz - 550 MHz
opp and l2 clock values are taken from WG2600HP3 GPL source code [1].
Due to a lack of devices, I didn't test the following features.
- SATA
- NAND flash memory controller
- SD
- USB
- GSBI2, GSBI7
- PCIE2
- GMAC0, GMAC3
Works properly:
- GSBI4 UART
- GSBI5 SPI
- GMAC1, GMAC2
- PCIE0, PCIE1
- MDIO0
Does not work properly:
- CPU SPC
- This can cause a system hang. Same as IPQ8065.
See 2336c2dbb1929837f7e42d4315c8073342a5b46b
[1] https://www.aterm.jp/function/wg2600hp3/appendix/opensource.html
Signed-off-by: Yanase Yuki <dev@zpc.sakura.ne.jp>
The Makefile is rejecting all files with for a given prefix (here
"board-plasmacloud_pa2200") when it didn't match a known suffix. Instead it
stops the build with an error like:
Makefile:135: *** Unrecognized board-file suffix '.ipq4019' for 'board-plasmacloud_pa2200.ipq4019'. Stop.
The correct suffix for the QCA4019/hw1.0 is qca4019 and not ipq4019.
Fixes: 4871fd2616ac ("ipq40xx: add support for Plasma Cloud PA2200")
Signed-off-by: Sven Eckelmann <sven@narfation.org>
The Makefile is rejecting all files with for a given prefix (here
"board-plasmacloud_pa1200") when it didn't match a known suffix. Instead it
stops the build with an error like:
Makefile:135: *** Unrecognized board-file suffix '.ipq4019' for 'board-plasmacloud_pa1200.ipq4019'. Stop.
The correct suffix for the QCA4019/hw1.0 is qca4019 and not ipq4019.
Fixes: ea5bb6bbfee0 ("ipq40xx: add support for Plasma Cloud PA1200")
Signed-off-by: Sven Eckelmann <sven@narfation.org>
FCC ID: U2M-EAP350
Engenius EAP350 is a wireless access point with 1 gigabit PoE ethernet port,
2.4 GHz wireless, external ethernet switch, and 2 internal antennas.
Specification:
- AR7242 SOC
- AR9283 WLAN (2.4 GHz, 2x2, PCIe on-board)
- AR8035-A switch (GbE with 802.3af PoE)
- 40 MHz reference clock
- 8 MB FLASH MX25L6406E
- 32 MB RAM EM6AA160TSA-5G
- UART at J2 (populated)
- 3 LEDs, 1 button (power, eth, 2.4 GHz) (reset)
- 2 internal antennas
MAC addresses:
MAC address is labeled as "MAC"
Only 1 address on label and in flash
The OEM software reports these MACs for the ifconfig
eth0 MAC *:0c art 0x0
phy0 --- *:0d ---
Installation:
2 ways to flash factory.bin from OEM:
- if you get Failsafe Mode from failed flash:
only use it to flash Original firmware from Engenius
or risk kernel loop or halt which requires serial cable
Method 1: Firmware upgrade page:
OEM webpage at 192.168.10.1
username and password "admin"
Navigate to "Upgrade Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9f670000`
wait a minute
connect to ethernet and navigate to
"192.168.1.1/index.htm"
Select the factory.bin image and upload
wait about 3 minutes
Return to OEM:
If you have a serial cable, see Serial Failsafe instructions
otherwise, uboot-env can be used to make uboot load the failsafe image
*DISCLAIMER*
The Failsafe image is unique to Engenius boards.
If the failsafe image is missing or damaged this will not work
DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait 3 minutes
connect to ethernet and navigate to 192.168.1.1/index.htm
select OEM firmware image from Engenius and click upgrade
Format of OEM firmware image:
The OEM software of EAP350 is a heavily modified version
of Openwrt Kamikaze. One of the many modifications
is to the sysupgrade program. Image verification is performed
simply by the successful ungzip and untar of the supplied file
and name check and header verification of the resulting contents.
To form a factory.bin that is accepted by OEM Openwrt build,
the kernel and rootfs must have specific names...
openwrt-senao-eap350-uImage-lzma.bin
openwrt-senao-eap350-root.squashfs
and begin with the respective headers (uImage, squashfs).
Then the files must be tarballed and gzipped.
The resulting binary is actually a tar.gz file in disguise.
This can be verified by using binwalk on the OEM firmware images,
ungzipping then untaring.
The OEM upgrade script is at /etc/fwupgrade.sh
Later models in the EAP series likely have a different platform
and the upgrade and image verification process differs.
OKLI kernel loader is required because the OEM software
expects the kernel to be no greater than 1024k
and the factory.bin upgrade procedure would
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035-A switch between
the SOC and the ethernet PHY chips.
For AR724x series, the PLL register for GMAC0
can be seen in the DTSI as 0x2c.
Therefore the PLL register can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x1805002c 1`.
uboot did not have a good value for 1 GBps
so it was taken from other similar DTS file.
Tested from master, all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: A8J-EAP600
Engenius EAP600 is a wireless access point with 1 gigabit ethernet port,
dual-band wireless, external ethernet switch, 4 internal antennas
and 802.3af PoE.
Specification:
- AR9344 SOC (5 GHz, 2x2, WMAC)
- AR9382 WLAN (2.4 GHz, 2x2, PCIe on-board)
- AR8035-A switch (GbE with 802.3af PoE)
- 40 MHz reference clock
- 16 MB FLASH MX25L12845EMI-10G
- 2x 64 MB RAM NT5TU32M16DG
- UART at H1 (populated)
- 5 LEDs, 1 button (power, eth, 2.4 GHz, 5 GHz, wps) (reset)
- 4 internal antennas
MAC addresses:
MAC addresses are labeled MAC1 and MAC2
The MAC address in flash is not on the label
The OEM software reports these MACs for the ifconfig
eth0 MAC 1 *:5e ---
phy1 MAC 2 *:5f --- (2.4 GHz)
phy0 ----- *:60 art 0x0 (5 GHz)
Installation:
2 ways to flash factory.bin from OEM:
- if you get Failsafe Mode from failed flash:
only use it to flash Original firmware from Engenius
or risk kernel loop or halt which requires serial cable
Method 1: Firmware upgrade page:
OEM webpage at 192.168.1.1
username and password "admin"
Navigate to "Upgrade Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9fdf0000`
wait a minute
connect to ethernet and navigate to
"192.168.1.1/index.htm"
Select the factory.bin image and upload
wait about 3 minutes
Return to OEM:
If you have a serial cable, see Serial Failsafe instructions
otherwise, uboot-env can be used to make uboot load the failsafe image
*DISCLAIMER*
The Failsafe image is unique to Engenius boards.
If the failsafe image is missing or damaged this will not work
DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait 3 minutes
connect to ethernet and navigate to 192.168.1.1/index.htm
select OEM firmware image from Engenius and click upgrade
Format of OEM firmware image:
The OEM software of EAP600 is a heavily modified version
of Openwrt Kamikaze. One of the many modifications
is to the sysupgrade program. Image verification is performed
simply by the successful ungzip and untar of the supplied file
and name check and header verification of the resulting contents.
To form a factory.bin that is accepted by OEM Openwrt build,
the kernel and rootfs must have specific names...
openwrt-senao-eap600-uImage-lzma.bin
openwrt-senao-eap600-root.squashfs
and begin with the respective headers (uImage, squashfs).
Then the files must be tarballed and gzipped.
The resulting binary is actually a tar.gz file in disguise.
This can be verified by using binwalk on the OEM firmware images,
ungzipping then untaring.
The OEM upgrade script is at /etc/fwupgrade.sh
Later models in the EAP series likely have a different platform
and the upgrade and image verification process differs.
OKLI kernel loader is required because the OEM software
expects the kernel to be no greater than 1536k
and the factory.bin upgrade procedure would
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035-A switch between
the SOC and the ethernet PHY chips.
For AR934x series, the PLL register for GMAC0
can be seen in the DTSI as 0x2c.
Therefore the PLL register can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x1805002c 1`.
Unfortunately uboot did not have the best values
so they were taken from other similar DTS files.
Tested from master, all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
The boards have equivalent hardware except for LEDs
and equivalent device config except for MACs
also use naming convention for mtd-concat partitions
to prepare for upcoming patch
"treewide: use more descriptive names for concatenated partitions"
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: A8J-ECB600
Engenius ECB600 is a wireless access point with 1 gigabit PoE ethernet port,
dual-band wireless, external ethernet switch, and 4 external antennas.
Specification:
- AR9344 SOC (5 GHz, 2x2, WMAC)
- AR9382 WLAN (2.4 GHz, 2x2, PCIe on-board)
- AR8035-A switch (GbE with 802.3af PoE)
- 40 MHz reference clock
- 16 MB FLASH MX25L12845EMI-10G
- 2x 64 MB RAM NT5TU32M16DG
- UART at H1 (populated)
- 4 LEDs, 1 button (power, eth, 2.4 GHz, 5 GHz) (reset)
- 4 external antennas
MAC addresses:
MAC addresses are labeled MAC1 and MAC2
The MAC address in flash is not on the label
The OEM software reports these MACs for the ifconfig
phy1 MAC 1 *:52 --- (2.4 GHz)
phy0 MAC 2 *:53 --- (5 GHz)
eth0 ----- *:54 art 0x0
Installation:
2 ways to flash factory.bin from OEM:
- if you get Failsafe Mode from failed flash:
only use it to flash Original firmware from Engenius
or risk kernel loop or halt which requires serial cable
Method 1: Firmware upgrade page:
OEM webpage at 192.168.1.1
username and password "admin"
Navigate to "Upgrade Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9fdf0000`
wait a minute
connect to ethernet and navigate to
"192.168.1.1/index.htm"
Select the factory.bin image and upload
wait about 3 minutes
Return to OEM:
If you have a serial cable, see Serial Failsafe instructions
otherwise, uboot-env can be used to make uboot load the failsafe image
*DISCLAIMER*
The Failsafe image is unique to Engenius boards.
If the failsafe image is missing or damaged this will not work
DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait 3 minutes
connect to ethernet and navigate to 192.168.1.1/index.htm
select OEM firmware image from Engenius and click upgrade
Format of OEM firmware image:
The OEM software of ECB600 is a heavily modified version
of Openwrt Kamikaze. One of the many modifications
is to the sysupgrade program. Image verification is performed
simply by the successful ungzip and untar of the supplied file
and name check and header verification of the resulting contents.
To form a factory.bin that is accepted by OEM Openwrt build,
the kernel and rootfs must have specific names...
openwrt-senao-ecb600-uImage-lzma.bin
openwrt-senao-ecb600-root.squashfs
and begin with the respective headers (uImage, squashfs).
Then the files must be tarballed and gzipped.
The resulting binary is actually a tar.gz file in disguise.
This can be verified by using binwalk on the OEM firmware images,
ungzipping then untaring.
The OEM upgrade script is at /etc/fwupgrade.sh
Later models in the ECB series likely have a different platform
and the upgrade and image verification process differs.
OKLI kernel loader is required because the OEM software
expects the kernel to be no greater than 1536k
and the factory.bin upgrade procedure would
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035-A switch between
the SOC and the ethernet PHY chips.
For AR934x series, the PLL register for GMAC0
can be seen in the DTSI as 0x2c.
Therefore the PLL register can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x1805002c 1`.
Unfortunately uboot did not have the best values
so they were taken from other similar DTS files.
Tested from master, all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
Commit 5fc28ef47959 ("ath79: Add support for Plasma Cloud PA300")
added the IMAGE/sysupgrade.bin/squashfs definition, which leaks into
other devices, resulting in sysupgrade.bin images that are actually
tarballs and do not boot when directly written to flash.
We can use the normal sysupgrade.bin command variable for this device.
Signed-off-by: Sven Wegener <sven.wegener@stealer.net>
[fix format, spelling]
Signed-off-by: David Bauer <mail@david-bauer.net>
b75bcad dhcpv6-ia: remove assignment equal to 0 checks
d1ae052 dhcpv6-ia: fix logic to include IA_PD prefix with lifetimes set to 0
9d5e379 dhcpv6-ia: fix prefix delegation behavior
Signed-off-by: Hans Dedecker <dedeckeh@gmail.com>
The image never worked in any release and is also broken in snapshots
due to stock bootloader not loading more than 4 MiB.
Hence it's better to remove the image for now, users who want to flash
OpenWrt on new devices may build LEDE 17.01 with everything possible
disabled to get a small enough and working factory image.
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
Lets use the generic upstream phy_print_status() instead of doing
something similar by hand.
Before:
ess_edma c080000.edma: eth1: GMAC Link is up with phy_speed=1000
After:
ess_edma c080000.edma eth1: Link is Up - 1Gbps/Full - flow control rx/tx
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
Since we now have a proper PHY driver for QCA807x and AR803x has already
been supported properly there is no need for the driver to be poking
on PHY registers for ethtool ops.
So, lets simply use the generic
phy_ethtool_ksettings_get/phy_ethtool_ksettings_set functions.
This also has the advantage of properly populating stuff other than
speeds like, transceiver type, MDI-X etc.
ethtool before:
root@OpenWrt:/# ethtool eth1
Settings for eth1:
Supported ports: [ TP MII ]
Supported link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
1000baseX/Full
Supported pause frame use: Symmetric Receive-only
Supports auto-negotiation: Yes
Supported FEC modes: Not reported
Advertised link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
1000baseX/Full
Advertised pause frame use: Symmetric Receive-only
Advertised auto-negotiation: Yes
Advertised FEC modes: Not reported
Link partner advertised link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
Link partner advertised pause frame use: No
Link partner advertised auto-negotiation: No
Link partner advertised FEC modes: Not reported
Speed: 1000Mb/s
Duplex: Full
Port: Twisted Pair
PHYAD: 4
Transceiver: internal
Auto-negotiation: on
MDI-X: Unknown
Supports Wake-on: d
Wake-on: d
Current message level: 0x00000000 (0)
Link detected: yes
ethtool after:
root@OpenWrt:/# ethtool eth1
Settings for eth1:
Supported ports: [ TP MII ]
Supported link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
1000baseX/Full
Supported pause frame use: Symmetric Receive-only
Supports auto-negotiation: Yes
Supported FEC modes: Not reported
Advertised link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
1000baseX/Full
Advertised pause frame use: Symmetric Receive-only
Advertised auto-negotiation: Yes
Advertised FEC modes: Not reported
Link partner advertised link modes: 10baseT/Half 10baseT/Full
100baseT/Half 100baseT/Full
1000baseT/Full
Link partner advertised pause frame use: Symmetric Receive-only
Link partner advertised auto-negotiation: Yes
Link partner advertised FEC modes: Not reported
Speed: 1000Mb/s
Duplex: Full
Port: Twisted Pair
PHYAD: 4
Transceiver: external
Auto-negotiation: on
MDI-X: off (auto)
Supports Wake-on: d
Wake-on: d
Current message level: 0x00000000 (0)
Link detected: yes
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
Since the new PHY driver manages each PHY individually and therefore
registers each PHY that is marked with gpio-controller; DT property as a
GPIO controller we need to convert old DT bindings to account for this.
Only 2 boards use this so its not much of an issue.
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
This adds necessary DT properties for QCA807x PHY-s to IPQ4019 DTSI.
Also adds the PSGMII PHY as it wont get probed otherwise.
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
PHY needs to be soft reset before starting it from ethernet driver as
AR40xx calibration will leave it in unwanted state.
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
Since we now have proper PHY driver for the QCA807x PHY-s, lets remove
PHY handling from AR40xx.
This removes PHY driver, PHY GPIO driver and PHY init code.
AR40xx still needs to handle PSGMII calibration as that requires R/W
from the switch, so I am unable to move it into PHY driver.
This also converted the AR40xx driver to use OF_MDIO to find the MDIO
bus as it now cant be set through the PHY driver.
So lets depend on OF_MDIO in KConfig.
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
This adds driver for the Qualcomm QCA8072 and QCA8075 PHY-s.
They are 2 or 5 port IEEE 802.3 clause 22 compliant
10BASE-Te, 100BASE-TX and 1000BASE-T PHY-s.
They feature 2 SerDes, one for PSGMII or QSGMII connection with MAC,
while second one is SGMII for connection to MAC or fiber.
Both models have a combo port that supports 1000BASE-X and 100BASE-FX
fiber.
Each PHY inside of QCA807x series has 2 digitally controlled output only
pins that natively drive LED-s.
But some vendors used these to driver generic LED-s controlled by
user space, so lets enable registering each PHY as GPIO controller and
add driver for it.
This also adds the ability to specify DT properties so that 1000 Base-T
LED will also be lit up for 100 and 10 Base connections.
This is usually done by U-boot, but boards running mainline U-boot are
not configuring this yet.
These PHY-s are commonly used in Qualcomm IPQ40xx, IPQ60xx and IPQ807x
boards.
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
With the reworked MDIO driver, EDMA will fail to get the MII BUS as it
used the MII BUS stored inside the MDIO structure private data.
This obviously does not work with the modernized driver, so lets switch
to using a purpose build of_mdio_find_bus() which will return the MII
BUS and only requires the MDIO node to be passed.
This is easy as we already have the node parsed.
Also, since we now require OF_MDIO add that as dependency.
Signed-off-by: Robert Marko <robert.marko@sartura.hr>