base-files: disable LEDs if default state is undefined

Set the default state for LEDs to off. When a trigger is set, the
trigger will turn the LED automatically on.

Currently LEDs might stay on, e.g. when the LED trigger is set to a
netdev trigger and the interface is never activated or the 'none'
trigger is selected without setting the 'default' option to 0 and it's
set for the LED indicating the system running state.

Using off as a default value is also consistent with the documentation
in the OpenWrt wiki.

Signed-off-by: David Bauer <mail@david-bauer.net>
This commit is contained in:
David Bauer 2020-07-26 22:37:53 +02:00 committed by CN_SZTL
parent b3264298e3
commit f97cbdda29
No known key found for this signature in database
GPG Key ID: 6850B6345C862176

View File

@ -21,7 +21,7 @@ load_led() {
config_get dev $1 dev
config_get ports $1 port
config_get mode $1 mode
config_get_bool default $1 default "nil"
config_get_bool default $1 default "0"
config_get delayon $1 delayon
config_get delayoff $1 delayoff
config_get interval $1 interval "50"